Welcome to Dongguan Yanke Intelligent Technology Co., Ltd
Soft package
contact us
Battery Cell Tester

I. Equipment Overview

This equipment is used to perform performance testing on batteries that have undergone the formation process, aiming to obtain key parameters such as capacity and internal resistance. It also classifies and grades the batteries.

II. Technical Parameters

Index ItemSpecification
Channels8
Input PowerAC 220V ±10% / 50Hz
Input Active Power400W
ResolutionAD: 24-bit; DA: 16-bit
VoltageConstant Voltage Range Control: 0.025V ~ 5V

Minimum Discharge Voltage: Up to 1V at both ends of upper and lower fixtures; up to 1.5V with 2m cable length

Accuracy: ±0.05% of FS

Stability: ±0.05% of FS
CurrentOutput Range per Channel:
Range 1: 0.5mA - 0.1A; Range 2: 0.1A - 3A; Range 3: 3A - 6A

Accuracy: ±0.1% of FS

Constant Voltage Cutoff Current:
Range 1: 0.2mA; Range 2: 6mA; Range 3: 12mA

Stability: ±0.05% of FS
PowerMaximum Output Power per Channel: 30W

Stability: ±0.1% of FS
TimeCurrent Rise Time: 20ms

Step Time Range: ≤ (365×24) hours per step
Time format supports 00:00:00:00 (h, min, s, ms)
Data RecordingRecording Conditions:
Minimum time interval: 100ms
Minimum voltage interval: 10mV
Minimum current interval:
Range 1: 0.2mA; Range 2: 6mA; Range 3: 12mA

Recording Frequency: 10Hz
ChargingCharging Modes: Constant current charging, constant voltage charging, constant current-constant voltage charging, constant power charging

Cutoff Conditions: Voltage, current, relative time, capacity, energy, -△V
DischargingDischarging Modes: Constant current discharging, constant voltage discharging, constant current-constant voltage discharging, constant power discharging, constant resistance discharging

Cutoff Conditions: Voltage, current, relative time, capacity, energy
Pulse ModeCharging: Constant current mode, constant power mode

Discharging: Constant current mode, constant power mode

Minimum Pulse Width: 500ms

Number of Pulses: A single pulse step supports 32 different pulses

Continuous Charge-Discharge Switching: A single pulse step can switch continuously from charging to discharging

Cutoff Conditions: Voltage, relative time
DCIR TestingSupports custom sampling points for DCIR calculation
CyclingCycle Test Range: 1 ~ 65535 cycles

Number of Steps per Cycle: 254

Cycle Nesting: Supports nesting function with a maximum of 3 layers
Protection● Power-off data protection
● Offline testing function
● Configurable safety protection conditions: voltage upper limit, voltage lower limit, current upper limit, current lower limit, capacity upper limit, delay time; reverse connection protection included
IP RatingIP20
Channel FeaturesConstant current source and constant voltage source adopt dual closed-loop structure
Channel Control ModeIndependent control
Voltage/Current Sampling4-wire connection
Noise<55dB
DatabaseUses MySQL database for centralized management of test data
Upper Computer CommunicationBased on TCP/IP protocol
Server OSWindows 7 / Windows 10
Data Output FormatEXCEL 2003, 2010; TXT
Server Disk Configuration500GB
Communication InterfaceEthernet port
Leakage Current<5μA

III. Installation Environment Requirements

  1. Power Supply: AC 220V/50Hz, power consumption approximately 400W.

  2. Equipment Specifications:

    1. Equipment weight: Approximately 15kg.

    2. Single unit dimensions: Approximately L (490mm) × W (400mm) × H (130mm).

    3. Exterior color: Light gray.

  3. Environmental Requirements:

    1. Ambient temperature: 25±5℃.

    2. Relative humidity: 30% ~ 75% RH; ensure on-site air is dry, well-ventilated, and free from acid/alkali corrosion.

    3. Grounding: Protective grounding required.