1. Equipment Overview

This equipment is used for performance testing of batteries that have undergone formation, to obtain their capacity, internal resistance, and other key parameters. It also classifies and grades the batteries.

1.jpg

2. Technical Parameters

IndicatorParameter
Channel Number8
Input PowerAC 220V ±10% / 50Hz
Input Active Power400W
ResolutionAD: 24-bit; DA: 16-bit
VoltageConstant voltage range control
Voltage Range0.025V~5V
Minimum Discharge VoltageBoth ends of the upper and lower fixtures can discharge to 1V; 1.5V with 2m cable length
Accuracy± 0.05% of FS
Stability± 0.05% of FS
CurrentOutput range per channel
Range 10.5mA-0.1A
Range 20.1A-3A
Range 33A-6A
Accuracy± 0.1% of FS
Constant Voltage Cutoff Current
Range 10.2mA
Range 26mA
Range 312mA
Stability± 0.05% of FS
PowerMaximum output power per channel
Stability± 0.1% of FS
TimeCurrent rise time
Step time range≤(365*24) hours/step
Time formatSupport 00:00:00:00 (h, min, s, ms)
Data Recording
Recording conditionsMinimum time interval: 100ms
Minimum voltage interval: 10mV
Minimum current interval
Range 10.2mA
Range 26mA
Range 312mA
Recording frequency10Hz
Charging
Charging modesConstant current charging, constant voltage charging, constant current constant voltage charging, constant power charging
Cutoff conditionsVoltage, current, relative time, capacity, energy, -△V
Discharging
Discharging modesConstant current discharge, constant voltage discharge, constant current constant voltage discharge, constant power discharge, constant resistance discharge
Cutoff conditionsVoltage, current, relative time, capacity, energy
Pulse Mode
ChargingConstant current mode, constant power mode
DischargingConstant current mode, constant power mode
Minimum pulse width500ms
Number of pulsesEach pulse step supports 32 different pulses
Continuous charge-discharge switchingA pulse step can achieve continuous switching from charging to discharging
Cutoff conditionsVoltage, relative time
DCIR TestSupports custom points for DCIR calculation
Cycle
Cycle test range1~65535 times
Number of steps per cycle254
Nested cyclesSupports nested cycles, up to 3 layers
Protection
Power-off data protection
Offline test function
Safety protection conditionsSettable parameters include: upper voltage limit, lower voltage limit, upper current limit, lower current limit, upper capacity limit, delay time, reverse polarity protection
IP Protection LevelIP20
Channel FeaturesDual closed-loop structure for constant current and constant voltage sources
Channel Control ModeIndependent control
Voltage and Current Detection SamplingFour-wire connection
Noise<55dB
DatabaseMySQL database for centralized test data management
Upper Computer Communication ModeBased on TCP/IP protocol
Server Operating SystemWindows 7/Windows 10
Data Output FormatEXCEL2003, 2010, TXT
Server Disk Configuration500GB
Communication InterfaceNetwork port
Leakage Current<5μA

3. Installation Environment Requirements

  1. Power Supply: AC220V/50Hz, power approx. 400W.

  2. Equipment Specifications:

    1. Equipment Weight: approx. 15kg.

    2. Single Machine Dimensions: approx. L (490mm) x W (400mm) x H (130mm).

    3. Appearance Color: Light Gray.

  3. Environmental Requirements:

    1. Ambient Temperature: 25±5℃.

    2. Relative Humidity: 30%~75% RCH, ensure the site is dry and well-ventilated, free from acid and alkali corrosion.

    3. Grounding: Protective grounding.